EasyManua.ls Logo

BenQ MP611 - Page 23

BenQ MP611
168 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
23
vibration should be done first.
Un-package Vibration
(Non-operating)
Sine-wave, 5~200Hz, 1.5G, all primary axis, one sweep (5 minutes)
per orientation, total of 15 min.
Un-package Shock
(Non-operating)
Waveform: Half sine
Faces: 6 sides/per orientation, 3 shocks
Duration: < 20 ms
Velocity accelerate: 50 G
Bench Drop 1. Pivot, 90 degree, sitting on right and left side, 1 drop per
orientation, total of 2 drops.
2. Bottom and opposite, 1 drop per orientation, drop height 5 cm,
totally 2 drops.
Security Lock 150N break away force
B2.2 Atmospherics Test
Temperature/Humidity,
(Operating)
Test condition: 0 ~ 40 , 10%~90%, no condensation℃℃
Test procedure:
25 /90%, 2hrs 40 /90%, 6hrs 0 , 6hrs ℃→℃→
40 /10%, 6hrs 25 /90%, 2hrs; (2 Cy℃→ cles)
Storage High Temperature /
Humidity
(Non-operating, with package)
Test condition: (-20°C ~ 60°C, 10% ~ 90% R.H.)
1. Storage high temperature / humidity exposure test:
25 /60%, 1hrs 60 /90%, 24hrs 25 /60%, 1hrs ℃→
2. Storage transportation test:
25 /60%, 1hrs ℃→-20 , 24hrs 25 /60%, 1hrs ℃→
60 /90%, 24hrs 25 /60%, 1 hrs℃→
Criteria Inspection:
1. The products should be operated normally at specified lower and
higher temperature environment.
2. The carton no crash and broken issue.
Altitude
Operating:
Without high altitude mode 0°C~35°C @ 0~1499m above sea level
With high altitude mode 0°C~30°C @ 1500~3000m above sea level
Non-operating: