42
4. Others
Item
Description
Power
good
signal
Active high after 5 Volt reach 95% of its rating and goes to logic low at
least 0.5ms before power falls to 90% of its rating
High voltage and high
temperature protection
To avoid user from the dangerous of HV and high temperature, when
front door of lamp case is opened whether intentionally or accidentally,
the power should be disconnected immediately. When the door is closed
again, the igniter restart sequence should be compliant to that is
described previously