CONTROL:
Offset Matte Density: 10
Only controls with numerical ranges support this relative mode.
Requesting a Status Dump
The client may request that Ultimatte resend the complete state of any status block by sending
the header of the block, followed by a blank line. In the following example, the client requests
Ultimatte resend the control status:
CONTROL:
ACK
CONTROL:
Matte Density: 0
Red Density: 0
Green Density: 0
...(Full list in Controls section)
File System
The client may request that Ultimatte load, save, delete, or rename a file. To load a file the client
should send the following block:
FILE:
Load: <filename>
Ultimatte will respond with an ACK followed by a Current File block or a Message block.
To save, delete, or rename a file the client should send one of the following blocks:
FILE:
Save: <filename>
FILE:
Delete: <filename>
FILE:
Rename: <filename>
To: <filename>
In each case Ultimatte will respond with an ACK followed by a File List block or a Message
block.
GPI Event List
The client may request that Ultimatte add, insert or remove an event to a GPI Event List by
sending an Insert GPI Event or Remove GPI Event command, followed by a blank line.
For example, to insert an event, the client should send the following block:
GPI:
ID: 1
Insert: <file n a m e>
At: -1
{The insertion index. A ‘-1’ represents the end of the list}
121

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Blackmagicdesign Smart Remote 4 and is the answer not in the manual?

Blackmagicdesign Smart Remote 4 Specifications

General IconGeneral
BrandBlackmagicdesign
ModelSmart Remote 4
CategoryMedia Converter
LanguageEnglish

Related product manuals