3.4 CongurationwithoutaDHCPserver
Without automatic assignment of an IP address by a DHCP server, it is necessary to manually assign a fixed IP
address.
To manually configure the Netsilon network settings, enter the following three parameters:
> IP address assignment
> This is a unique address assigned to Netsilon by the network administrator. Ensure that the chosen
address is available.
> Subnet mask
> The subnet mask defines the number of bits taken by the IP address. The number of bits used in the
netmask may range from 8 to 30 bits.
> Gateway
> The gateway address is required if communication with Netsilon is outside the local network. By
default, the gateway is disabled.
To configure these three parameters, use the Netsilon network menu, via its control panel:
10:54.32
Tues19SEP2016
10:54.32
Tues19SEP2016
S y s t e m o k 
Network õ
Network ok
USBtransfer õ
DisplayETH0 ok
Config.ETH0 õ
DHCP:YESú
IPaddressAutook
IPAddress:
192.168.1.0ok
IPmask:
255.255.255.000ok
IPgateway:
---.---.---.---ok
Savinginprogress...
Resettinginpro-
gress...
DHCP:NOú
FixedIPaddresso k
Config.ETH0 ok
õ
Enter the values with the and
keys.
Note:thesevaluesaredetermined
bythenetworkadministrator.