4.7.2. PULSEexpansioncard(ref.907942)
The PULSE expansion card enables wired time distribution by pulse every minute or ½ minute at 24VDC parallel.
To configure the PULSE output, follow these steps:
1) TIME menu > Outputs > Slot D: 24V pulse:
2) Configure the output by clicking , and the following window will appear:
3) Select the time zone which will be transmitted via the PULSE expansion card output.
4) Select the impulse type: Minute or ½ minute.
5) Set the pulse length in seconds.
6) Enable the output using the
button, then save.
The button can be used to configure the dial time
1
and its polarity (negative or positive).
1
The dial time is the reference time on which the network clocks are positioned before commissioning or during a time
reset.