EasyManua.ls Logo

Bosch DIVAR 3000 - RS232 Port Connections; Alarm I;O Connections

Bosch DIVAR 3000
94 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 7.1: RS485 connector
Signal name Pin number Description
TX + 1 Data transmission
TX - 2 Data transmission
GND 3 Shield
Max. signal voltage is -8 to +12 V. The recommended cable cross section is AWG 28-16
(0.08-1.5 mm2).
RS232 port connections
The RS232 port can be used to connect different devices:
Console
PTZ Matrix - a pan and tilt control unit (using RS232 to Biphase converter)
The device type and required settings can be assigned in the menu (Settings > System >
Serial Port).
Specifications
Connector type: 9-pole D-type male connector
Maximum input voltage: ±25 V
Communication protocol: Output signals according EIA/TIA-232-F
Figure 7.2: RS232 serial port
Signal name
Pin number Description
DCD_in 1 Carrier detection signal (not used)
RX 2 RS232 receive signal
TX 3 RS232 transmit signal
N/C 4 No connection
System ground 5 System ground
N/C 6 No connection
RTS 7 RS232 request to send signal
CTS 8 RS232 clear to send signal
N/C 9 No connection
Alarm I/O connections
Alarm inputs and outputs are fitted as screw down terminal blocks on the unit. Cable cross
section is AWG 26-16 (1.29 to 0.4 mm
2
).
7.3
7.4
DIVAR 2000 / DIVAR 3000 / DIVAR
5000
Hardware setup | en 29
Bosch Security Systems Operation Manual 2016.09 | v1.0 | AM18-Q0717