Alarm
Use the Alarm menu to specify the desired behavior for a Motion detect, Video loss, Input
alarm, System alarm, or Alarm out; also define how alarms are acknowledged.
Motion detect
Here you can set events that can be used to trigger motion detection alarms (as configured by
the recorder software, and only if the attached cameras do not have IVA). If required, use the
<Default> button to reset all detect fields to the factory default.
See the following descriptions for the full list of settings:
Channel: Select the channel(s) to activate the recording function when a motion detection
alarm occurs (make sure you have selected “Motion” in Main Menu > Setting > Schedule).
Enable: Select to enable motion detection
Motion configured by (only for IP cameras): Assign here if Camera (Default) or Recorder
software is used for motion detection.
Region: Click <Set> for a new interface screen where you can assign a motion detection zone
(only possible if Recorder software is selected for detection - see above). This screen shows a
matrix of small rectangular zones on the screen. The normal default when you open this
screen for each camera channel is that the complete screen is colored and ‘armed’ (activated
for motion detection). A black (or dark) area signals a disarmed zone. Set detection region(s)
as follows:
1. Left-click the mouse and drag it over a region where you want to disable (disarm) motion
detection. Notice that the selected zones become dark.
2. Release the mouse button when you have selected a complete area to be disabled for
motion detection.
3. Now repeat this action for other areas on the screen to be disabled. If you want to ‘rearm’
a disabled area again, or you make a mistake, simply select the region again with the left-
mouse button (the region will be colored again).
4. After setting all the motion detection zones for a channel, return to the ‘Detect’ screen by
right-clicking the mouse (or click the ‘Enter’ button). If you click the ESC button to exit
the region setup screen, the zone setup will not be saved.
5. Always remember to click <Save> on the ‘Motion Detect’ screen to save the current
setup.
Period: Click <Set> for a new interface screen where you can organize time periods for detect
activation as follows:
1. Select the check box on the left for the day where you require detection (or ‘All’ for all
days).
2. If you do not require motion detection for the whole day, hold down the left mouse
button and drag it over segments of the time bar to assign begin and end times for
deactivating motion detection (the default is a colored bar for 24-hour detection). Use the
<Set> button to assign precise deactivate times if required.
3. When you have correctly assigned a day, continue with the next day. If the time periods
are the same as the first day, then a quick way to do this is:
click <Set> for the time bar to copy
Under the ‘Copy’ line, select each of the days that have a similar setup (checkbox is
ticked) and click <Save>. Use ‘All’ to select all days.
the same time periods for the first day now apply to all selected days
4. When ready, click <OK> to return to the Alarm or Detect screen. Do not forget to click
<Save> here to save your settings.
8.4
8.4.1
44 en | Settings
DIVAR 2000 / DIVAR 3000 / DIVAR
5000
2016.09 | v1.0 | AM18-Q0717 Operation Manual Bosch Security Systems

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch DIVAR 3000 and is the answer not in the manual?

Bosch DIVAR 3000 Specifications

General IconGeneral
AC input voltage100 - 240 V
AC input frequency50 - 60 Hz
Power consumption (max)20 W
Storage temperature (T-T)0 - 93 °C
Operating temperature (T-T)0 - 40 °C
Storage relative humidity (H-H)0 - 95 %
Operating relative humidity (H-H)-40 - 70 %
Sustainability certificatesRoHS
CertificationEMC, LVD, UL, cUL, CAN/CSA, BIS, RCM, ACMA EMC, CE, FCC
On/off switchYes
Product colorBlack, Silver
Rack capacity-
Bit rate24000 Kbit/s
Display modesLive view
Playback modesFast play, Forward, Frame by Frame, Reverse, Slow play
Input bandwidth320 Mbit/s
Number of users128 user(s)
Recording modesManual, Schedule, Stop
Output bandwidth256 Mbit/s
Maximum resolution3840 x 2160 pixels
Alarm input channels16
Video input channels16 channels
Alarm output channels3
Supported resolutions3840×2160, 1920×1080, 1280×1024, 1280×720, 1024×768, 970x576, 704x576, 352x576, 352x288, 176x144, 960x480, 704x480, 352x480, 352x240, 176x120
Video recording modes720p, 1080p
Video formats supportedH.264, H.265, M-JPEG
RS-232 ports1
Audio RCA inputs4
Networking standardsIEEE 802.3
USB 2.0 ports quantityUSB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them.
Ethernet LAN data rates10, 100, 1000 Mbit/s
Ethernet LAN (RJ-45) ports2
Supported network protocolsHTTP, HTTPS, TCP/IP, IPv4/IPv6, UPnP, RTSP, UDP, SMTP, NTP, DHCP, DNS/DDNS, IP Filter, PPPoE, FTP
Copper ethernet cabling technology10BASE-T, 100BASE-T, 1000BASE-T
Wi-FiNo
HDD capacity- GB
HDD interfaceSerial ATA
Maximum storage capacity6 TB
Mobile operating systems supportedAndroid, iOS
Weight and Dimensions IconWeight and Dimensions
Depth323 mm
Width375 mm
Height53 mm
Weight4130 g