EasyManuals Logo

Brocade Communications Systems MLXe Series User Manual

Brocade Communications Systems MLXe Series
274 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #198 background imageLoading...
Page #198 background image
186 Brocade MLXe Series Hardware Installation Guide
53-1003030-01
Using alarms to collect and monitor device status
5
If an optic is removed or not present, a major alarm is reported and logged and any existing alarms
are cleared from the current alarm log.
NOTE
Alarms are not generated for optic device insertion.
Switch fabric element
If a switch fabric element cannot be accessed, a major alarm is reported and logged.
Chassis fans, power supplies, and optics
If there is an indication that a single fan has failed, a major alarm is reported and logged on the
tray. If an incompatible fan tray is detected, a major alarm is reported and logged on the tray. When
a fan tray is removed, any existing alarms are cleared and a major alarm is reported and logged on
the tray.
If a power supply is installed but powered down, a minor alarm is reported and logged. If a power
supply is installed incorrectly, a major alarm is reported and logged. If a power supply is not
present, a major alarm is reported and logged.
Clearing the alarm history log
Use the clear alarm command to remove some or all of the current alarms. Once the alarm is
cleared, it is removed from the current alarm database and is no longer available even though the
condition might still exist. The alarm is kept in the history log.
If you clear all alarms, a single entry is added to the history that indicates all alarms have been
cleared.
To clear all alarms from the alarm logs, enter the following command:
Brocade# clear alarm all
For example, if you want to clear all alarms from the alarm logs on a specific optic in slot 9 of the
interface module in slot 1, enter the following command:
Brocade# clear alarm lp 1 optic 9
Disabling SNMP trap generation and logging
With the introduction of the alarm feature, you may want to disable some SNMP trap generation
and logging to save space.
To disable SNMP fan change-trap generation, enter the following command:
Brocade(config)# no snmp-server enable traps fan-speed-change
To disable Syslog fan-speed-change logging, enter the following command:
Brocade(config)# no logging enable fan-speed-change
For additional information on SNMP traps and logging, refer to the Unified MIB Reference.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Brocade Communications Systems MLXe Series and is the answer not in the manual?

Brocade Communications Systems MLXe Series Specifications

General IconGeneral
BrandBrocade Communications Systems
ModelMLXe Series
CategoryControl Unit
LanguageEnglish

Related product manuals