220 Brocade MLXe Series Hardware Installation Guide
53-1003030-01
Port specifications for all router models
7
Operating environment
Table 44 provides the operating environment specifications for Brocade MLXe routers.
Storage environment
Table 45 provides the storage environment specifications for the Brocade MLXe routers.
Safety agency approvals
• CAN/CSA-C22.2 No. 60950-1-07/UL60950-1 – Second Edition, Safety of Information
Technology Equipment
• EN 60825-1 Safety of Laser Products – Part 1: Equipment Classification, Requirements and
User’s Guide
• EN 60825-2 Safety of Laser Products – Part 2: Safety of Optical Fibre Communications
Systems
• EN 60950-1:2006\IEC 60950-1:2005, Second Edition, Safety of Information Technology
Equipment
Electromagnetic approvals
• FCC Part 15, Subpart B (Class A)
• EN 55022 (CE mark) (Class A)
• EN 55024 (CE mark) (Immunity) for Information Technology Equipment
• ICES-003 (Canada) (Class A)
• AS/NZ 55022 (Australia) (Class A)
• VCCI (Japan) (Class A)
• EN 61000-3-2
• EN 61000-3-3
• EN 61000-6-1
Port specifications for all router models
This section describes port specifications for all router models.
Console port pin assignments
The console port is a standard male DB-9 connector, as shown in Figure 126. For information
about how you can use this port, refer to “Console port” on page 10.
TABLE 44 Brocade MLXe router operating environment
Operating temperature Relative humidity Operating altitude
(0° – 40°C) 32° – 104°F 5 to 90%, at (40°C) 104°F, non-condensing (0 – 3km) 0 – 10,000 ft
TABLE 45 Brocade MLXe router storage environment
Storage temperature Storage humidity Storage altitude
(-25° – 70°C) -13° – 158°F 95% maximum relative humidity,
non-condensing
(0 – 4500 meters) 0 – 15,000 ft