Brocade MLXe Series Hardware Installation Guide 217
53-1003030-01
Chapter
7
Hardware Specifications
This chapter describes hardware specifications for Brocade MLXe routers.
Hardware specifications for Brocade MLXe routers
The following sections describe hardware specifications for Brocade MLXe routers.
Power specifications
The following power supply frequency requirements apply to Brocade MLXe-4, Brocade MLXe-8,
and Brocade MLXe-16 routers:
AC Input Rating: 100 to 240V, 50/60 Hz, 16.0 A maximum per power supply
1200W Power Output for 1200W PSU (100-240V)
1200W Power Output for 1800W PSU (100-180V)
1800W Power Output for 1800W PSU (180-240V)
AC Operating Voltage Range: 90 to 264V, 50/60 Hz
Inrush current <60A peak for any initial current surge or spike of 10mS or less at either
cold or warm start. Any additional inrush current surges or spikes in the form of AC cycles
or multiple AC cycles greater than 10mS and less than 150mS will be <25A peak.
DC Input Rating: -48V
40A maximum per power supply (1200W PSU)
60A maximum per power supply (1800W PSU)
DC Operating Range: -40 to -60V
Inrush current <80A peak for any initial current surge or spike of 10mS or less at either
cold or warm start.
The following power supply frequency requirements apply to the Brocade MLXe 32-slot routers:
AC Input Rating: 200 to 240V, 50/60 Hz, 16.0 A maximum per power supply
AC Operating Voltage Range: 180 to 264V
Inrush current <60A peak for any initial current surge or spike of 10mS or less at either
cold or warm start. Any additional inrush current surges or spikes in the form of AC cycles
or multiple AC cycles greater than 10mS and less than 150mS will be <25A peak.
DC Input Rating: -48V
75A maximum per power supply (2400W PSU)
80A maximum per power supply (3000W PSU)
DC Operating Range: -40 to -60V
Inrush current <70A peak for any initial current surge or spike of 10mS or less at either
cold or warm start.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Brocade Communications Systems MLXe Series and is the answer not in the manual?

Brocade Communications Systems MLXe Series Specifications

General IconGeneral
BrandBrocade Communications Systems
ModelMLXe Series
CategoryControl Unit
LanguageEnglish

Related product manuals