Table 1-11 Process and Ambient Temperature Limits (continued)
T6 T6 T5 T4 T3 T2
A
pproval
type
Housing type
Ambient
Temperature (°C)
Without
Inductive
Alarm
With Inductive
Alarm
With or without
Inductive
Alarm
With or without
Inductive
Alarm
With or without
Inductive
Alarm
With or without
Inductive
Alarm
-40 to 40 85 85 100 126 N/A N/A
-40 to 45 85 85 100 115 N/A N/A
-40 to 50 85 85 100 104 N/A N/A
-40 to 55 85 84 94 94 N/A N/A
-40 to 60 84 76 84 84 N/A N/A
-40 to +65 76 69 76 76 N/A N/A
-40 to +70 *69 N/A 69 69 N/A N/A
-40 to 40 85 85 100 135 200 N/A
-40 to 45 85 85 100 135 194 N/A
-40 to 50 85 85 100 135 167 N/A
-40 to 55 85 85 100 135 138 N/A
-40 to 60 85 85 100 110 110 N/A
-40 to +65 85 69 86 86 86 N/A
-40 to +70 *69 N/A 69 69 69 N/A
-40 to 40 85 85 100 135 200 267
-40 to 45 85 85 100 135 200 221
-40 to 50 85 85 100 135 182 182
-40 to 55 85 85 100 135 149 149
-40 to 60 85 85 100 119 119 119
-40 to +65 85 69 91 91 91 91
-40 to +70 *69 N/A 69 69 69 69
NOTE
IntrinsicSafety/NonͲSparking/Enclosuredust
cULus
Stainless
Steel
Stainless
Steel High
Temp
Aluminum
* Maximum Ambient Temperature for Inductive alarm = +66 °C
Maximum Process Temperature (°C)
Meter Option Without Digital Display With or without Digital Display