2-5 Installation of Flowmeter
Recommended installation for Models MT3809 and MT3810 is as follows:
a. Carefully remove the covers from each end of the owmeter. The oat
may be xed to avoid damage during transport. These plugs must be
removed before use.
b. Install the owmeter with the inlet at the bottom and the outlet at the
top.
c. When installing the owmeter in the process line, follow accepted
plumbing practices.
i. For anged meters (without lining):
Select bolts and gaskets (customer supply) in keeping with the ange
pressure rating or the operating pressure. Also note corrosion
resistance and thermal stability.
Align gasket and tighten nuts using the torques specied for the
relevant pressure ratings. Advised bolting acc. ASTM A307 Grade B
ii. For threaded meters:
Follow the applicable installation instructions for threaded
connections.
Important: ensure that thread sealing material does not get into the

Table of Contents