Installation and Operation Manual
X-VA-MT3809G-MT3810G-eng
Part Number: 541B182AAG
July, 2018
Models MT3809G & MT3810G
ow path. Loose pieces can cause obstruction inside the
measurement section of the meter, and potentially even blockage of
the measurement oat within the measurement tube.
iii. For ETFE lined meters:
Select bolts and gaskets (customer supply) in keeping with the ange
pressure rating or the operating pressure. Also note corrosion
resistance and thermal stability.
Important: the inside diameter of the anges deviates from the
standard dimensions. Enlarge the ange gaskets to the appropriate
size.Align gasket and tighten nuts using the torques specied in
Table 2-1
Important: PTFE is deformable under pressure in the cold state. Do
not exceed maximum torque.
d. Install the owmeter within 5° of true vertical. Use of a level is
recommended to determine the proper alignment.
e. When the process temperature is 300°C / 572°F or above
insulation is required on the meter body and anges. The
insulation is installed between the indicator housing and the
body and anges. Do not wrap the indicator with insulation.
Figure 2-1 Typical Bypass Installation
Table 2-1 Maximum Torques Model MT3809 ETFE
Recommended insulation materials are calcium silicate, cellular glass
or mineral wool with a thermal conductivity of .083 W/m-K at 300°C /
572°F.
DIN
DN PN inch lb 150lb 300lb Nm ft.lbs
15 40 1/2" 150/300 4x M12 4x 1/2" 4x 1/2" 3.4 2.5
25 40 1" 150/300 4x M12 4x 1/2" 4x 5/8" 6.5 4.8
40 40 1,5" 150/300 4x M16 4x 1/2" 4x 3/4" 13.6 10
50 40 2" 150/300 4x M16 4x 5/8" 8x 5/8" 23.6 17.4
DIN ASME ASME
Connection size Stud bolts Max. torque