11.
Changing special functions using the memory switches
• Turn
the
dial
while
pressing
the
STEP
BACK
switch
to
change
the
values.
SWNo.
Possible
Units
Initial
Explanation
setting
range
value
memo-30
1--999
X10ms
10
Time
until
feed
mechanism
starts
moving
after
work
clamp
has
lifted.
memo-31
1--4
-
1
Changes
the
feed
speed.
1 (Fast) - 4
(Slow)
Changes
the
possible
sewing
speed
for
a
given
stitch
length.
1 (Fast)
-7
(Slow)
1
(2,
700/3
mm),
2 (2,600/3
mm),
3 (2,500/3
mm),
memo-32
1-7
-
3
4
(2,300/3
mm),
5 (2,000/3
mm),
6
(1
,800/3
mm),
7 (1,200/3
mm)
Settings 1
and
2 are outside the warranty specification
at
the
time of shipment
from
the factory.)
memo-33
1--10
x7.5°
5
Changes the feed timing
1 (Fast) - 5 (standard) -
10(Siow)
memo-34
1-5
-
0
Number
of
low-speed
stitches
sewn
at
400
spm
at
sewing
start
Solenoid
ON
time
changes
when
work
clamp
is
being
lowered
memo-35
10-60
Xms
40
(solenoid
specifications only)
10
60
(Quiet)
(High
work clamp capacity)
The
solenoid
ON
time
when
the
presser foot
is
raised
memo-36
1-3
-
1
changes.
(Standard) 1 - 3 (Upper limit)
Specifies the enlargement
and
reduction method
when
memo-37
0-3
-
0
reading
from
a
200
floppy disk.
0:
Automatic correction;
1:
No
conversion;
2:
326,
326A,
326L,326LA;3:341,341A,342,342A
memo-38
-
-
0
-
memo-39
-
-
0
-
memo-3A
-
-
0
-
memo-3b
-
-
0
-
memo-3c
-
-
0
-
memo-3d
-
-
0
-
memo-3E
-
-
0
-
memo-3F
-
-
0
-
BAS-341 E • 342E