Confidential
2-20
(2) Connect the two flat cables (CN1, CN4) and one connector (CN8) into the Laser unit.
Note:
When connecting the flat cable(s), do not insert it at an angle. After insertion, check that
the cable is not at an angle.
Fig. 2-30
(3) Assemble the Scanner cover with the nine cup S M3x6 Taptite screws (8 pieces on the top
and 1 piece on the front side).
Note:
When assembling the Scanner cover, secure the Screws in the order of the numbers
which are indicated on the Scanner cover.
Fig. 2-31
Laser unit
<Front>
Scanner cover
Taptite, cup S M3x6
Taptite, cup S M3x6
Taptite, cup S M3x6
Taptite, cup S M3x6
Frame unit
<Front>