BTL-5000 SERIES
USER'S MANUAL
page 51 of 56
Type: 5820SL 5825SL 5820L 5825L 5830L 5835L 5840S 5840SL 5840L
5860L
Number of therapies 4 4 3 3 4 4 5 6 5 7
Electrotherapy 2 2 2 2 3 3 4 4 4 6
Ultrasound therapy 1 1 1 1
Laser therapy 1 1 1 1 1 1 1 1 1
Patient cardfile (positions) min. 150 min. 150 min. 150 min. 150 min. 150 min. 150 min. 150 min. 150 min. 150 min. 150
User programs min. 150 min. 150 min. 150 min. 150 min. 150 min. 150 min. 150 min. 150 min. 150 min. 150
User sequences min. 50 min. 50 min. 50 min. 50 min. 50 min. 50 min. 50 min. 50 min. 50 min. 50
Step of setting of values standard standard standard standard standard standard standard standard standard standard
Encyclopaedia x x x x x x x x x x
Preset diagnoses
Preset programs
Preset sequences
Programs
Interconnection with PC optional optional optional optional optional optional optional optional optional optional
Print optional optional optional optional optional optional optional optional optional optional
Language versions x x x x x x x x x x
Sound schemes x x x x x x x x x x
Display, diagonal b/w
14.6 cm
b/w
14.6 cm
b/w
14.6 cm
b/w
14.6 cm
b/w
14.6 cm
b/w
14.6 cm
b/w
14.6 cm
b/w
14.6 cm
b/w
14.6 cm
b/w
14.6 cm
Screen saver
x x x x x x x x x
x
Colour schemes
Recent performed therapies 20 20 20 20 20 20 20 20 20 20
Electro parameters:
Channel mode CC / CV CC / CV CC / CV CC / CV CC / CV CC / CV CC / CV CC / CV CC / CV CC / CV
Galvanic, Iontophoresis x x x x x x x x x x
Träbert, Farad, Neofarad x x x x x x x x x x
Diadynamics x x x x x x x x x x
TENS x x x x x x x x x x
Rectangular pulses x x x x x x x x x x
Triangular pulses x x x x x x x x x x
Exponential pulses x x x x x x x x x x
Combined pulses x x x x x x x x x x
Interrupted pulses x x x x x x x
Pulse modulation: x x x x x x x x x x
random frequency sweep x x x x x x x x x x
burst, surges x x x x x x x x x x
Stimulation pulses x x x x x x x x x x
Russian stimulation x x x x x x x x x x
2-pole interference x x x x x x x x x x
4-pole interference x x x x x x x x x x
Isoplanar field (interference) x x x x x x x
Vector field (interference) x x x x x x x
Electrodiagnostics: x x x x x x x
I/t curve (memory position) min. 50 min. 50 min. 50 min. 50 min. 50 min. 50 min. 50
HVT optional
H – waves x x x x x x x
Spastic currents x x x x
Microcurrents x x x x x x x
Leduc's current x x x x x x x
Mid-frequency surges x x x x
Ultrasound parameters:
Head of 4 cm
2
, 1 and 3 MHz x x x x
Head of 1 cm
2
, 1 and 3 MHz optional optional optional optional
Detection of contact continuou
s
continuou
s
continuou
s
continuou
s
Continuous operation mode x x x x
Pulse operation mode x x x x
Duty factor x x x x
Laser parameters:
Max. laser output, 685 nm 50 mW 50 mW 50 mW 50 mW 50 mW 50 mW 50 mW 50 mW 50 mW
Max. laser output, 830 nm 400 mW 400 mW 400 mW 400 mW 400 mW 400 mW 400 mW 400 mW 400 mW
Continuous operation mode x x x x x x x x x
Pulse operation mode x x x x x x x x x
Duty factor x x x x x x x x x
Nogier frequencies x x x x x x x x x
EAV frequencies x x x x x x x x x