8 UNITS CONFIGURATIONS
8.1 TABLE OF CONFIGURATIONS OF THE COMBINED DEVICES BTL
5000 COMBI
Type: 5800SL 5810S 5810S2 5810SL 5810L 5810L2 5820S 5825S
Number of therapies 2 2 3 3 2 3 3 3
Electrotherapy 1 1 1 1 1 2 2
Ultrasound therapy 1 1 2 1 1 1
Laser therapy 1 1 1 2
Patient cardfile (positions) min. 150 min. 150 min. 150 min. 150 min. 150 min. 150 min. 150 min. 150
User programs min. 150 min. 150 min. 150 min. 150 min. 150 min. 150 min. 150 min. 150
User sequences min. 50 min. 50 min. 50 min. 50 min. 50 min. 50 min. 50 min. 50
Step of setting of values standard standard standard standard standard standard standard standard
Encyclopaedia x x x x x x x x
Preset diagnoses
Preset programs
Preset sequences
Programs
Interconnection with PC optional optional optional optional optional optional optional optional
Print optional optional optional optional optional optional optional optional
Language versions x x x x x x x x
Sound schemes x x x x x x x x
Display, diagonal
b/w
14.6 cm
b/w
14.6 cm
b/w
14.6 cm
b/w
14.6 cm
b/w
14.6 cm
b/w
14.6 cm
b/w
14.6 cm
b/w
14.6 cm
Screen saver x x x x x x x x
Colour schemes
Recent performed therapies 20 20 20 20 20 20 20 20
Electro parameters:
Channel mode CC / CV CC / CV CC / CV CC / CV CC / CV CC / CV CC / CV
Galvanic, Iontophoresis x x x x x x x
Träbert, Farad, Neofarad x x x x x x x
Diadynamics x x x x x x x
TENS x x x x x x x
Rectangular pulses x x x x x x x
Triangular pulses x x x x x x x
Exponential pulses x x x x x x x
Combined pulses x x x x x x x
Interrupted pulses x
Pulse modulation: x x x x x x x
random frequency sweep x x x x x x x
burst, surges x x x x x x x
Stimulation pulses x x x x x x x
Russian stimulation x x x x x x x
2-pole interference x x x x x x x
4-pole interference x x
Isoplanar field (interference) x
Vector field (interference) x
Electrodiagnostics: x
I/t curve (memory position) min. 50
HVT optional optional optional optional optional
H waves x
Spastic currents
Microcurrents x
Leduc's current x
Mid-frequency surges
Ultrasound parameters:
Head of 4 cm
2
, 1 and 3 MHz x x x x x x
Head of 1 cm
2
, 1 and 3 MHz optional optional optional optional optional optional
Detection of contact continuous continuous continuous continuous continuous continuous
Continuous operation mode x x x x x x
Pulse operation mode x x x x x x
Duty factor x x x x x x
Laser parameters:
Max. laser output, 685 nm 50 mW 50 mW 50 mW 50 mW
Max. laser output, 830 nm 400 mW 400 mW 400 mW 400 mW
Continuous operation mode x x x x
Pulse operation mode x x x x
Duty factor x x x x
Nogier frequencies x x x x
EAV frequencies x x x x
Devices of types 5815 and 5821 have similar properties as 5810, but have some additional types of currents.