Troubleshooting Guide
2-6
Panel display
Code
(last 4
digits)
Large LCD
Small
LCD 1
Small
LCD 2
Explanation/Detection sequence
Remedial Action
(★: Reference fault
isolation procedure
or tool)
1043 GL2: W0504
This command is not
supported.
GL2:W05
04
HP/GL2 error; Invalid command
A command that is not defined in HP-GL/2
or HP RTL is included.
Verify the data
and fix it.
1044 HP/GL2 error; current point missing
Invalid data is included.
Verify the data
and fix it.
1045 HP/GL2 error; Drawing limit
Invalid coordinates are included.
Verify the data
and fix it.
1047 GL2: W0903
The memory is full.
GL2:W09
04
HP/GL2 error; replot buffer overflow
Data storage buffers have run short.
①Reduce the size
of rendering
data.
②Replace with
HP RTL data for
manipulation
with On The Fly.
1048 GL2: W0904
The memory is full.
GL2:
W0903
HP/GL2 error; polygon buffer overflow
The size of drawing data exceeds the
processing capacity.
①Reduce the size
of rendering
data.
②Replace with
HP RTL data for
manipulation
with On The Fly.
* On The Fly: The method to transmit data in sequence from paper. The software that generates HP-GL/2 data has this option