Set the operating mode using the rotary switch (Fig. 108,6).
In winter operation "Heater and production of hot water" (Fig. 108,5) the do-
mestic water is automatically heated up when the heater is switched on. If
the heater switches off after the required room temperature has been
reached, the domestic water will continue to heat up until the set water tem-
perature has been reached.
A temperature sensor next to the panel measures the room temperature.
In the operating mode "Only heater" (Fig. 108,4) the heater can be operated
with an empty domestic water container.
Open the regulator tap on the gas bottle and the gas isolator tap
"Heater/boiler".
Turn the temperature control knob (Fig. 108,8) on the operating unit to
the desired heating level.
Set rotary switch (Fig. 108,6) to winter operation "Only heater"
(Fig. 108,4) or to winter operation "Heater and production of hot water"
(Fig. 108,5).
The green indicator lamp (Fig. 108,7) is on.
The circulation fan automatically switches on when the heater is activated.
Turn the rotary switch (Fig. 108,6) to "" (Fig. 108,3).
Close the gas isolator tap "Heater/boiler" and the regulator tap on the
gas bottle.
After switching off the heater, the circulation fan may still run for a moment
to use up the residual heat.
It is not possible to heat the vehicle in "Summer" operating mode. In this op-
erating mode, only the domestic water is heated up to 40 °C or 60 °C.
Open the regulator tap on the gas bottle and the gas isolator tap
"Heater/boiler".
Set the rotary switch (Fig. 108,6) on the operating unit (Fig. 108) to
"Summer operation" (Fig. 108,1 or 2).
The yellow indicator lamp (Fig. 108,9) is illuminated during the heating up
period. When the set water temperature is reached, the period of heating up
is finished and the yellow indicator lamp fades.
In case of fault, the indicator lamp (Fig. 108,9) on the operating unit glows
red (see section 15.6).
Set the rotary switch (Fig. 108,6) on the operating unit (Fig. 108) to "".
Close the gas isolator tap "Heater/boiler" and the regulator tap on the
gas bottle.
Selecting operating mode:
Winter operation
Switching on:
Switching off:
Summer operation
Switching production of hot
water on:
Switching production of hot
water off: