Gas system
84
Capron - 3141417 - 03/20 - EHG-0021-02EN
8
8.4 Changing gas bottles
When changing gas bottles, do not smoke or create any open fire.
When you have changed the gas bottle, check whether gas escapes
at the connection points and unions. Use a leakage search spray to
spray the relevant connection point or union. These agents are availa-
ble at the accessories shop.
Fig. 93 Gas bottle connection
Open the external flap for the gas bottle compartment (see section 7.2).
If there is a guard plate, fold it down.
Close the regulator tap (Fig. 93,4) on the gas bottle. Pay attention to the
direction of the arrow.
Hold the gas pressure regulator (Fig. 93,2) and open the knurled nut
(Fig. 93,3) (normally a left-hand thread).
Remove the gas pressure regulator and the gas tube (Fig. 93,1) from
the gas bottle.
Release the fixing belts and remove the gas bottle.
Place a filled gas bottle in the gas bottle compartment.
Fix gas bottle in place with the fixing belts.
Position the gas pressure regulator (Fig. 93,2) and the gas tube
(Fig. 93,1) on the gas bottle and tighten the knurled nut (Fig. 93,3) by
hand (normally a left-hand thread).
If there is a guard plate, fold it upwards.
Close the external flap (see section 7.2).