Fault Cause Remedy
Refrigerator does not
switch on when operating
in 230 V mode
No 230 V power supply Connect 230 V power
supply
230 V automatic circuit
breaker has triggered
Switch on 230 V auto-
matic circuit breaker
Refrigerator does not
switch on when operating
in 12 V mode
Contacts on the plug
and/or in the socket have
oxidised and/or are con-
taminated
Clean contacts and spray
with contact spray
Short circuit caused by
water in the plug and/or
socket
Open plug and/or socket,
dry out, and spray with
contact spray
Cable interruption on the
plug and/or socket
Open plug and re-connect
cable
Fuse on the power supply
unit is defective
Replace the fuse on the
power supply unit
Disconnector relay in the
power supply unit is de-
fective
Contact customer service
Refrigerator does not
switch on when operating
in gas mode
Lack of gas
Open regulator tap and
gas isolator tap
Connect a full gas bottle
Air in the gas pipe Repeat ignition 3 or
4 times
Cobwebs or burnt residue
in the burning chamber
Remove the ventilation
grill on the outside of the
vehicle and clean the
burning chamber
The desired refrigerating
temperature is not
achieved
Incorrect setting
Set the temperature with
the temperature controller
Too much fresh food put
into it
Set the temperature with
the temperature controller
Insufficient ventilation of
unit
Check if ventilation grills
are covered; remove co-
vers if necessary
Remove ventilation grills
and clean the space be-
hind them (of leaves etc.)
Ambient temperature is
too high
Remove the ventilation
grills periodically