115
10
Fig. 115 Operating controls for gas
cooker
Fig. 116 Operating controls for gas
cooker (alternative)
Fig. 117 Operating controls for gas
cooker (alternative)
Open the regulator tap on the gas bottle and the gas isolator tap
"Cooker".
Open the gas cooker cover.
Depending on the model, fold out or set up the flame protection.
Turn the control knob (Fig. 115,1, Fig. 116,1 or Fig. 117,1) on the burner
you wish to use to the ignition position (large flame).
Press the control knob down and hold it.
Manual ignition: Light the burner with a gas lighter, a match or other suit-
able means of lighting.
Electronic ignition: Press rocker switch (Fig. 117,1). Ignition sparks are
generated at the burner.
Once the flame is burning, the control knob must be held down for an-
other 10 to 15 seconds, until the thermocouple automatically keeps the
gas supply open.
Release the control knob and turn to the desired setting.
If ignition is unsuccessful, repeat the entire procedure.
Turn the control knob to the 0-position. The flame fades.
Close the gas isolator tap "Cooker" and the regulator tap on the gas bot-
tle.
Switching on:
Switching off: