8200-M585-O1 Rev D 210 Installation & Technical 24
KEYPAD FUNCTIONS, CONT.
24-Hour Format Selected In Setup (td=24)
1. With the display showing HoUr=, press the ENTER key.
2. If the time displayed is correct, press the ENTER key and proceed to step 4.
3. If the displayed time is incorrect, use the numeric keys to enter the correct time and
press the ENTER key. Note that with the 24-hour format selected, entering all times
after noon (12:00 PM), you must add 12 to the time, i.e. 3 PM would be 1500.
4. The display will show dAtE=. Press the ENTER key.
5. If the date displayed is correct, press the ENTER key to proceed to the consecutive
number prompt, CnC n=.
6. If the date displayed is incorrect, use the numeric keys to enter the correct date and
press the ENTER key to proceed to the consecutive number prompt. Remember to
enter the date in the same format (month-day-year or day-month-year) as selected by
the USA setup parameter. Note that with the USA=YES setting, the date format is
month-day-year.
Consecutive Number
Consecutive Number is a printable number (see PRINT TABS in SETUP AND
CALIBRATION section) corresponding to the number of consecutive weighments that have
been printed. The consecutive number is incremented (if not set to “0”) every time a weight
is printed. The consecutive number will be reset to the number entered at the CnC n=
prompt.
If the consecutive number displayed is correct, press the ENTER key to resume normal
operation. If the consecutive number displayed is incorrect, use the numeric keys to enter
the correct consecutive number (up to 6 digits) and press the ENTER key to resume normal
operation.
PRESET KEY
This key is used to perform numerous functions. Note that the various functions of this key
are dependent upon the selected Mode of Operation setting. Those functions are as follows:
ID Storage (oPER=1)
If the setup parameter ALAr? is YES, the ALrRt prompt will be displayed. Press the
ENTER key and the alarm weight value will be displayed. If the value is acceptable, press
the ENTER key, otherwise, use the numeric keys to enter the new alarm weight value and
press the ENTER key.
The ALrti prompt will be displayed, press the ENTER to display the number of seconds
that the alarm output (PWC1) is to be turned on when the scale weight exceeds the alarm
weight. The alarm time can be from 0 to 99 seconds.