8200-M585-O1 Rev D 210 Installation & Technical 25
KEYPAD FUNCTIONS, CONT.
Digital Fill Control (oPER=2)
If Stor is enabled (Stor=YES), you will first be prompted for the stored preset ID
(Stor=). Press the ENTER key to see the current ID. If it is correct then press the ENTER
key, otherwise enter the desired stored preset ID to be recalled from memory and press the
ENTER key.
Single Speed operation: (SPEED=1)
The FiLL= prompt is displayed, press the ENTER key. The fill weight value is displayed, if
the value is acceptable, press the ENTER key, otherwise, use the numeric keys to enter the
new fill weight value and press the ENTER key.
The Trin= prompt is displayed, press the ENTER key. The trim weight value is displayed,
if the value is acceptable, press the ENTER key, otherwise, use the numeric keys to enter
the new trim weight value and press the ENTER key.
Two Speed operation: (SPEED=2)
The FASt= prompt is displayed, press the ENTER key. The fast weight value is displayed,
if the value is acceptable, press the ENTER key, otherwise, use the numeric keys to enter
the new fast weight value and press the ENTER key.
The SLo= prompt is displayed, press the ENTER key. The slow weight value is displayed, if
the value is acceptable, press the ENTER key, otherwise, use the numeric keys to enter the
new slow weight value and press the ENTER key.
The Trin= prompt is displayed, press the ENTER key. The trim weight value is displayed,
if the value is acceptable, press the ENTER key, otherwise, use the numeric keys to enter
the new trim weight value and press the ENTER key.
If the GATE sequence is set to 3 (chatter-gate), the Ct on= prompt will be displayed; press
the ENTER key. The chatter-gate on time is displayed, if the value is acceptable, press the
ENTER key, otherwise, use the numeric keys to enter the new chatter-gate time and press
the ENTER key.
If Stor is enabled (Stor=YES), you can store/modify a permanently stored preset ID by
pressing the key followed by the PRESET key, then enter the desired stored preset ID
(S
tor=?) then press the ENTER key.
Preset Weight Comparator (oPEr=3)
If the Preset Weight Comparator mode of operation (oPEr =3) was selected, the PSEt1=
prompt will be displayed. Press the ENTER key and the currently stored weight value for
PRESET #1 will be displayed. If the value displayed is acceptable, pres the ENTER key,
otherwise, use the numeric keys to enter the new preset value and press the ENTER key.
The setup parameter oPEr=3, p out=, determines the number of preset weight
comparators that will be displayed and prompted for.
There can be up to 8 Preset weight comparators.