5–3 62-12259
3. The hour meter screen will display with a 15-second timeout. Press the or key to scroll through the
available selections. With the desired sub-menu highlighted, press the “=” key to view the data.
4. The number of meters displayed depends on the settings for this unit. Press the BACK key to return to the
HOUR METERS screen or the EXIT key to return to the default screen. Once activity requiring use of Tech-
nician mode is complete, Technician mode should be manually canceled, refer to Figure 5.1.
5.2.2 Inactive Alarms
There are two sections in the Alarm list: an active alarm section and an inactive alarm section. The APX Control
System can hold up to 16 alarms in the combined lists. The lists can be read via the display screen or using TRU-
Tech. Alarms in these sections are in the order in which the alarms activate and inactivate, respectively. On
startup, all alarms are moved to the inactive list. If an inactive alarm becomes active, the alarm is moved from the
inactive list to the active list.
Each alarm can only be present in either the active or inactive list at any given time. As conditions change, alarms
may be moved from the active list to the inactive list and back.
Alarms are also recorded in the data recorder. They are recorded at the time they occur (become active), and the
time they become inactive.
Instructions for reading and clearing the Inactive Alarms are provided in Figure 5.3. for a complete list of Alarms
and troubleshooting information Refer to Section 9.
NOTE
The Inactive Alarm List is also called the Technician’s List. Only qualified refrigeration technicians
should access the inactive list. It is not intended for the use of drivers or advanced users.
STANDARD HOUR METERS (2 OF 3)
SWITCH ON HOURS
BACK
EXIT
ENGINE HOURS
1400 HOURS
1050 HOURS
TOTAL RUN HOURS
1182 HOURS
LOCK
SCREEN
END OF LIST
OTHER METERS and COUNTERS
BACK
EXIT
METER/COUNTER LIST
LOCK
SCREEN
END OF LIST
MAINTENANCE METERS
BACK
EXIT
TIME LEFT TO (METER NAME) #####
LOCK
SCREEN
END OF LIST
RESET PM HOUR METERS (2 OF 2)
TIME LEFT TO SWITCH ON HOURS
BACK
EXIT
TIME LEFT TO ENGINE HOURS
0
0
RESET
END OF LIST
Number of hours
or cycles
High Speed Hours
Standby Hours
Start Cycles
Switch On Hours
Engine Hours
Compressor Hours
As Configured
Standby Protect Hours
Engine Protect Hours
Switch On Protect Hours
Engine Sleep Hours
Switch On Sleep Hours
High Speed Hours
Start Cycles
To reset an hour meter, highlight the meter
and press the RESET soft key. In this example,
the Switch On Meter would be reset.
STANDBY HOURS
123 HOURS