7–83 62-12259
00223 Engine Maintenance Due
ACTIVATION: The Engine Maintenance Hour Meter time has expired.
UNIT CONTROL: Engine and Electric Operation: Alarm Only. Alarm Light will NOT be turned on.
RESET CONDITION: Alarm may be manually reset using the display mounted keys.
Corrective Actions:
1. Check Unit Maintenance Records - Schedule unit into service facility for maintenance. Must be done
soon!
2. Perform Maintenance - Perform appropriate engine and unit maintenance. Follow instructions on proper
maintenance form.
3. Reset Engine Maintenance Hour Meter
a. Check that the Engine Maintenance Hour Meter interval is set for your requirements. Reset
configured Interval if required.
b. Reset Engine Maintenance Hour Meter for the next service interval. Hour Meter reset is a Functional
Parameter. Follow maintenance interval recommendations.
00224 Standby Maintenance Due
ACTIVATION: The Standby Hour Meter time has expired.
UNIT CONTROL: Engine and Electric Operation: Alarm Only. Alarm Light will NOT be turned on.
RESET CONDITION: Alarm may be manually reset via keypad.
Corrective Actions:
1. Check Unit Maintenance Records - Schedule unit into service facility for maintenance. Must be done
soon!
2. Perform Maintenance - Perform appropriate engine and unit maintenance. Follow instructions on proper
maintenance form.
3. Reset Standby Hour Meter
a. Check that the Standby Maintenance Hour Meter interval is set for your requirements. Reset
configured Interval if required.
b. Reset Standby Maintenance Hour Meter for the next service interval. Hour Meter reset is a
Functional Parameter. Follow maintenance interval recommendations.