62-12259 3–28
WAKE UP TIME OFF
ON
Set a time when Sleep mode will wake up, ranging from 1 hour
to eight days from current time.
Overrides
OVERRIDE DOOR
SWITCH SHUTDOWN
(DS)
OVERRIDE REMOTE
SWITCH 1
SHUTDOWN
(REMS1)
OVERRIDE REMOTE
SWITCH 2
SHUTDOWN
(REMS2)
NO
YES
If the switches are all configured “Switch Not Installed”, this
parameter will not display.
NO = the system will respond to the switch as configured.
YES = the configured action on activation of the switch will be
overridden and the action will be alarm only. The purpose of
this setting is to temporarily override the Configuration setting
in situations where shutdown or speed change is not desired.
NO S/B POWER SHUT DOWN UNIT
SWITCH TO DIESEL
When set to Shut Unit Down, this function will override the No
A/C Power configuration parameter.
Viewing Preferences
DISPLAY
TEMPERATURE IN
°F
°C
Temperatures will display in either Fahrenheit (°F) or Celsius
(°C). (for North American Units, this function may be locked)
DISPLAY PRESSURE
IN
PSIG
BAR
Pressure will display in either psig or (bar). (for North American
Units, this function may be locked)
DATE forMAT MM/DD/YYYY
DD/MM/YYYY
Date will display in either US (MM/DD/YYYY) or European
(DD/MM/ YYYY) format.
ALARM
DESCRIPTIONS
YES
NO
YES = In the Driver Mode, the alarm code and alarm
description will be displayed.
NO = In the Driver mode, only the alarm code will be displayed.
CONTRAST 0 to 63 (In single
digit increments)
35
Higher numbers increase the contrast of the display screen.
Table 3–2 Functional Parameters