7–63 62-12259
P00141 Pretrip Stopped by User
ACTIVATION: Pretrip cycle was stopped by user before the Pretrip cycle ended automatically.
UNIT CONTROL: Engine and Electric Operation: Alarm Only.
RESET CONDITION: Alarm may be manually reset using the display mounted keys or by turning the unit
off, then back on again.
NOTE
Follow the steps below until a problem is found. Once a repair or correction has been made, clear
the alarm(s). (Refer to Note 1 in Notes Section) Operate the unit through the appropriate modes to
see if any active alarm occurs. Continue with the steps below as necessary.
Corrective Actions:
1. Check for Any Pretrip Alarms - Scroll the alarm list for any Active Pretrip alarms. Alarm conditions must
be corrected and the alarm cleared to continue.
2. Rerun Pretrip Check (If Desired)
a. Clear Active Alarm List, then run Pretrip and check for any new alarms. Unit is in Pretrip. Check for
any new alarms.
b. Allow to terminate automatically. Pretrip cycle operates normally.
P00151 Check Glow Circuit
ACTIVATION: The circuit current draw is outside the normal range.
UNIT CONTROL: Engine and Electric Operation: Pretrip will fail in test 2 and display “PRETRIP FAIL
AND COMPLETED”.
RESET CONDITION: Auto reset if Pretrip is started again or alarm may be manually reset using the
display mounted keys or by turning the unit off then back on again.
Corrective Actions: Check glow plug operation.