Page 17
Programming Single Unit Overview
Programming Single Unit Overview
The units emit various audio tones to respond to input and to indicate
certain conditions.
System Feedback / Responses (Beeps)
Programming Responses:
Voice Response Description
4 Short Beeps: Enter command System is waiting for a latch command
by user with entry code
3 Short Beeps: Exit program Exiting from program mode
2 Short Beeps: Valid step Valid step entered in programming mode
1 Long Beep: Invalid step Invalid step entered during programming
2 Long Beeps: Duplicate code Duplicate code entered during
programming a new code
3 Long Beeps: Capacity reached The new code is rejected because
database is full
1-7 Short Beeps: Unit 1-7 Give feedback of system ID number to
user in programming mode: keypad or
phone
1 Short Beep: Digit Keyname Echo each key press on user’s touch tone
phone or key press while in programming
mode
Other Response:
Voice Response Description
4 Long Beeps: Chime System starts up
Visual Responses:
LED Status Description
Solid Red Idle power, door 1 is locked
Blinking Red Strikes and Out for door 1
Solid Green Granted access for door 1
Blinking Green Latch for door 1 is unlocked