CF Control Operation and functions
07/2017
Page
27
Parameters
Values - Setting limits Factory
setting
32
Switching mark 3 condition
: Switching mark inactive
: Filter pump ON

:
Filter pump OFF

35
Switching mark 4 hour (0
-
23)
36
Switching mark 4 minute (0
-
59)
37
Switching mark 4 condition
: Switching mark inactive
: Filter pump ON
: Filter pump OFF

40
Time in hours (0
-
23)
41
Time in minutes ( 0
-
24)
80
Release dosing chlorine (relay 1)
0: not released 1: released
1
81
Release dosing pH reduce (relay 2)
0:
not released 1: released
1
82
Release heating (relay 3)
0: not released 1: released
1
84
pH control direction relay 2
0: reduce 1: raise
0
85
Probe voltage pH (in mV)
only display
86
Slope of pH probe
8
only display
87
Zero point pH probe
Fehler! Textmarke nicht definiert.
only display
98
Software version: serial number
only display
99
Software version: year
only display
Table 2 Code B (NN) in addition:
Parameters
Function Factory
setting
02
P
-
ba
nd pH (0.2
3)
1 pH
03
Hysteresis pH (0.0
1.0)
0.1 pH
05
P
-
band redox (20
-
300)
100 mV
10
Switch-on delay dosing and heating in
min. (1-30)
Switch off = 0
5min
11
Max. dosing time relay 1
in min (1-90)
No monitoring = 0
60 min.
8
Reset of calibration values (86,87) via parameter 00 with function 999 (see chapter 15.1)