10 Commissioning
10.1 What to do before commissioning the system
For all swimming pools and whirlpools, it is very important that pool hydraulics, water
system and overall technical equipment are properly planned, constructed and, of
course, operated accordingly. The following points are of particular importance in this
respect:
- Compliance with our recommendation of a minimum operating time of
the filter system/measuring, control and dosing system of 12 hours per
day.
- Filter backwash at least once a week, or more often in case of
increased usage.
- Removal of fine dirt particles by means of flocculation.
- Regular pool cleaning with a suction machine (e.g. AquaCat).
If swimming pool and technical equipment are already existing and you want to
switch to the CF Control 100 automatic measuring, control and dosing system, the
following is to be considered:
- Check the complete system with respect to its technical operation
including the required pool hydraulics.
- The existing pool water should preferably be drained off if it has been in
the pool for more than 6 months and/or if the water was treated with
organic chlorine or alternative products before. Please consult your
service partner.
- The pool has to be thoroughly cleaned before being re-filled with fresh
water.
- Check the filter material and replace it, if necessary.
- Wash the pool surface (particularly important in case of foil surfaces)
with a suitable algaecide (e.g. dinolgin, dinozon, dinocid special) before
re-filling.
- Then fill immediately with fresh water and put into operation.
When all dosing systems are connected, connect the unit to the mains.
When the LED „Dosing -– on“ lights, switch the dosing off by pressing .
Open the ball valves (0181-178-01) of the measuring cell at the water sampling point
and the sample water return completely.
WARNING:
Adjust the flow at the measuring cell.