Operating instructions
CF Control 100
12 Alarm messages
12.1 List of error messages:
The following error codes are displayed, depending on the type of error:
- – when the chlorine dosing container is empty (contacts 17, 18
closed)
14
- – when the pH dosing container is empty (contacts 19, 20 closed)
14
- – when the sample water monitoring has responded
(see chapter 11.2)
- – when a leakage is detected
- – when the max. dosing time for chlorine is exceeded
- – when the max. dosing time for pH reduce is exceeded
- – when the temperature measurement of the pool water is not
working properly
- – when the temperature measurement of the solar absorber is not
working properly
- – when the max. dosing quantity per day is exceeded
12.2 Resetting of alarms
Alarms that are not terminated automatically after the cause has been eliminated
must be acknowledged by you. The button is pressed for this purpose. (Please
press for more than 2 seconds.) Each time this button is pressed, all current alarms
are reset, provided the particular error has been removed/corrected.
14
With optional suction lance with container empty signal equipment (accessory)