Operating instructions
CF Control 100
Page
26
02/2017
6) Confirm your selection by pressing , the value on the right stops flashing,
which means that the value has been stored.
After that, you can use or to adjust further parameters or you can quit
the parameter settings by pressing .
6.2 Table of setting parameters
Table 1 Code A (00)
Parameters
Values - Setting limits Factory
setting
00
CODE
01
Set point pH (6.5
-
8.5)
7.2 pH
04
Set point redox (350
-
950)
600 mV
07
Measured value water temperature in 0.1°C
only disp
lay
08
Measured value temperature at solar
absorber in 0.1 °C (is only displayed when
solar heating has been activated)
only display
09
Setpoint water temperature in 0.1°C
(5
-
40)
28 °C
20
Switching mark 1 hour (0
-
23)
21
Switching mark 1 minute (0
-
59)
22
Switching mark 1 condition
: Switching mark inactive
: Filter pump ON
: Filter pump OFF

25
Switching mark 2 hour (0
-
23)
26
Switching mark 2 minute (0
-
59)
27
Switching mark 2 condition
: Switching mark inactive
: Filter pump ON

:
Filter pump OFF

30
Switc
hing mark 3 hour (0
-
23)
31
Switching mark 3 minute (0
-
59)
Value flashes