Operating instructions
CF Control 100
Page
28
02/2017
Attention: Please do not change the parameters in the fields highlighted in grey in
this manual.
Parameters
Function Factory
setting
12
Max. dosing time relay 2
in min (1-90)
No monitoring = 0
60 min.
15
Max. daily dosing quantity relay 1
in 0.1 liter, (1-300)
No monitoring = 0
0
16
Max. daily dosing quantity relay 2
in 0.1 liter, (1-300)
No monitoring = 0
0
50
Mode relay 1:
„0“ = On/ Off; „1“ = Pulse frequency
„2“ = Pulse / Pause
2
55
Mode relay 2:
„0“ = On/ Off; „1“ = Pulse frequency
„2“ = Pulse / Pause
2
88
Max. dosing capacity pump DES
in 0.1 l/h (5
-
80)
3 l/h
89
Max. dosing capacity pump pH
in 0.1 l/h (5
-
80)
3 l/h
90
Operating mode
9
1
91
Disinfection mode
9
1
92
Blocking the calibration
0: A,B,C
-
1: B,C
0
6.3 Explanations of setting parameters
6.3.1 Code [Parameter 0]
There are 3 access levels that you can access by using codes.
This is to protect the device from unauthorized operation.
A) Code A - 00: End user code
B) Code B – NN.: Code for pool dealers / service staff
C) Code C – NN: Code for dinotec factory service.
The table in chapter 6.2 lists the setting parameters that are available in different
access levels.
9
After changing the mode, a different manual is applicable!