CF Control Maintenance and servicing
Page
55
02/2017
Outdoor pools at
the end of the
season
Buffer solution pH 7 / 4
Wintering in non-frost-proof
room
- Measuring amplifier
- pH electrode
- Redox electrode, if existing
Flow valve/pipe
Dosing liquids:
- pH correction chemicals
- dinochlorine
Dosing pumps
Wintering in frost-proof room
- Measuring amplifier
- pH electrode
- Redox electrode, if existing
- Sample water extraction and
return
- Dosing liquids
- Dosing pumps
Cannot be used, order in due
time before the start of the
season
OFF
Take out of the flow valve,
close contacts with protective
cap, put into a small bottle
containing potassium chloride
solution or water to prevent
drying
Empty and bring into frost-
proof
room
Close properly and keep in a
cool and dry place.
Should be used up, if possible
Pump with clean water, switch
to OFF
OFF
Remain in the flow valve
together with water
Close
See above
see above