MT2398C
RH (Relative Humidity) Settings
1. Select the Main menu button. Select the
Ventilation Settings button.
2. Select the RH Influence button.
3. Actual Influence- The actual amount of
influence time the RH function is adding to
the minimum ventilation timer. The con-
trol may not always add the full amount of
time if the amount of influence would add
up to be more than the maximum allowed
setup in the (Ventilation Settings/Set
Temp) screen.
5. Low Control Limit- If the RH in the house is below this setting than the control will
subtract an increment of on time to the minimum ventilation timer down to the minimum
setting is (Ventilation Settings/Set Temp) screen.
Note: If the RH is between the High and Low Control limit, then the control will neither
add or subtract on time to the minimum ventilation timer. The RH is check 30 seconds
prior to an ON time cycle of the minimum ventilation timer.
4. High Control Limit- If the RH in the
house is above this setting than the control will add
an increment of on time to the minimum ventilation timer up to the maximum amount of
influence allowed or the maximum possible amount of ventilation on time that is set in the (Ventilation
Settings/Set Temp) screen.
3
4
5

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Chore-Time Chore-Tronics 3 Control and is the answer not in the manual?

Chore-Time Chore-Tronics 3 Control Specifications

General IconGeneral
BrandChore-Time
ModelChore-Tronics 3 Control
CategoryHome Automation
LanguageEnglish