1. Select the Main menu button. Select the Ventilation Settings button.
2. Select the Set Temp Timer button.
Note: Only the values with a white background
are editable. All other boxes are information only.
3. Set temperature
Set Temperature is a very important pa-
rameter. All other temperatures are de-
pendant on the set temperature. When the
set temperature is changed, all other tem-
perature settings are also changed by the
same amount to maintain the same tem-
perature differences relative to the set
temperature.
4. Day
Day is the age of the animals or birds.
Changing the age with Set temp and or
Min Vent curve on will change their values to the current curve values.
3
4
5. Current Min.Vent. ON Time
Current Min. Vent. ON Time is the current amount of ON time the fans assigned to the Minimum
Ventilation Timer will run while cycling on the timer. This amount of time compines both Tem-
perature and if being used RH influence. If (TMP) is displayed the Min. Vent. Fan (s) are on by
temperature.
6. The status of the Set Temperature and Min Vent curve and curve values are displayed at the
bottom of this screen.
The Temp Curve and Min Vent Curve "on" indications are not editable. They only indicate that
the curve(s) are "on" and the curve's value. If a curve is not "on", there is no indication in this area.
The values shown at the bottom of the screen are the current curve's values. If the actual values
are different, the difference represents the "offset". Editing the actual values to be the same as the
values displayed at the bottom of the screen will erase the offset(s). An "offset" is caused if you
change a value when its curve is on.
5
6