Control Setup Chore-TronicsĀ® 3 Control
31
MT2398C
Digital Inputs
The Digital Input Screens are very similar to the Analog Input screens and setup the same way. In these
screens the Control is told what digital inputs (Water Meters, Feed Scales, Airspeed Sensor, Low Water
Pressure Switch, Flush Feed Back, Auger Run Time Alarm, etc.) are connected to the Control and where.
All digital or pulsed inputs that are connected to the Control must be assigned a board number and an
Input number. It is highly recommended that the Input Decal located inside the main box of the Control
be completed before entering information in this screen.
Board- This is the number of the board where the water meter or other digital input device is connected.
Board number 0 is the I/O Board. If the sensor is connected to an additional digital input board, then the
board number matches the address of the add on board (see the installation section of this manual).
Input- This is Input number that the water meter or other digital input device is connected to on the board.
For the I/O Board the input number will be 1 thru 8. If the sensor is connected to an additional
analog input board then the input number will be 1-4.
Name- A name can be entered for the Water meter, feed scale, and auxiliary digital inputs using the al-
phanumeric keypad. The name entered here will appear in the Auxiliary Data and History screens.
Select Add and the next Sensor will appear in the list.
Select Remove and the last Sensor in the list will be deleted.
Type and Number
2. Select the Type & Number button.
3. Select the Digital inputs you have connect-
ed to the Chore-Tronic's 3.
Digital Inputs
1. Select the Main menu button. Select the Setup but-
ton from the Main Menu screen. Finally, se-
lect the Digital inputs Button.

Table of Contents