Control Installation
Control Installation Chore-Tronics® 3 Control
90
MT2398C
Mounting the Control
56 Output Control Mounting
A 56 Output Chore-Tronics
®
3 Control consists of a Main Box and a Relay Box. The
Main Box requires a minimum mounting area of 21 in. [53 cm] x 21 in. [53 cm] (See
Figure below).The Relay Box requires 22 in. [56 cm] x 27 in. [69 cm]. This
dimension allows extra room for the control doors to open. The boxes should be
mounted level and square on a solid backing using the mounting holes provided.
Note:
When mounting the Main Box and the Relay Box, make sure the two boxes are as
close together as possible to reduce the likely hood of a communication failure. Make
sure that the Relay Box is mounted so that the relay indicator lights are visible when
standing at the Main Box.
21" Min. 22" Min.
43" Min.
21" [53cm] Min.
Figure 11. 56 Output Control Mounting