Programmable DC Electronic Load 63600 Series Operation & Programming Manual
5-34
ADV:TIM:TRIG:VSTA 500mV Set start voltage = 0.5V
ADV:TIM:TRIG:VSTA MAX Set start voltage = maximum
value.
ADV:TIM:TRIG:VSTA MIN Set start voltage = minimum
value.
Query Syntax: ADVance:TIMing:TRIG:VSTArt?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit = Volt]
Query Example: ADV:TIM:TRIG:VSTA?
ADV:TIM:TRIG:VSTA? MAX
ADV:TIM:TRIG:VSTA? MIN
ADVance:TIMing:VALue
Type: Channel-Specific
Description: Set load value according to the run mode in Timing mode. Notice
every time when the run mode of timing is changed this setting will
be reset to zero.
Setting Syntax: ADVance:TIMing:VALue<space><NRf+>[suffix]
Setting Parameters:Refer to respective specification for valid value range.
Setting Example:
When ADV:TIM:MODE set to CC mode, then
ADV:TIM:VAL 0.5 Set current = 0.5A
ADV:TIM:VAL 500mA Set current = 0.5A
ADV:TIM:VAL MAX Set current = maximum value.
ADV:TIM:VAL MIN Set current = minimum value.
When ADV:TIM:MODE set to CR mode, then
ADV:TIM:VAL 0.5 Set resistance = 0.5Ω.
ADV:TIM:VAL 500mΩ Set resistance = 0.5Ω.
ADV:TIM:VAL MAX Set resistance = maximum value.
ADV:TIM:VAL MIN Set resistance = minimum value.
When ADV:TIM:MODE set to CP mode, then
ADV:TIM:VAL 0.5 Set power = 0.5W.
ADV:TIM:VAL 500mW Set power = 0.5W.
ADV:TIM:VAL MAX Set power = maximum value.
ADV:TIM:VAL MIN Set power = minimum value.
Query Syntax: ADVance:TIMing:VALue?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit = Ampere | Ohm | Watt]
Query Example: ADV:TIM:VAL?
ADV:TIM:VAL? MAX
ADV:TIM:VAL? MIN
[ADVance:]USER:WAVeform:NSELect
Type: Channel-Specific
Description: Set the active waveform to run for user-define waveform function.
Setting Syntax: [ADVance:]USER:WAVeform:NSELect<space><NRf+>
Setting Parameters:<NRf+>, 1 ~ 10, Resolution = 1, Unit = None
Setting Example: USER:WAV:NSEL 5 Set active waveform = 5
USER:WAV:NSEL MAX Set active waveform = maximum
value.
ADV:USER:WAV:NSEL MIN Set active waveform = minimum
value.
Query Syntax: [ADVance:]USER:WAVeform:NSELect?[<space><MAX | MIN>]
Return Parameters:<NR1>, [Unit = None]
Query Example: USER:WAV:NSEL?

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Chroma 63600 Series and is the answer not in the manual?

Chroma 63600 Series Specifications

General IconGeneral
Series63600
Operating Temperature0°C to 40°C
ModesCC, CV
InterfaceGPIB, USB
ProtectionOCP, OTP, OVP
Voltage Resolution1mV
CoolingForced Air

Related product manuals