aaa accounting system rp-failover
To create an accounting list to send rp-failover or rp-switchover start or stop accounting messages, use the
aaa accounting system rp-failover command in global configuration mode. To disable the system accounting
for rp-failover, use the no form of this command.
aaa accounting system rp-failover {list_name {start-stop| stop-only}| default {start-stop| stop-only}}
no aaa accounting system rp-failover {list_name {start-stop| stop-only}| default {start-stop| stop-only}}
Syntax Description
Specifies the accounting list name.
list_name
Specifies the default accounting list.default
Enables the start and stop records.start-stop
Enables the stop records only.stop-only
Command Default
None
Command Modes
Global configuration mode
Command History
ModificationRelease
This command was introduced.Release 4.2.0
Usage Guidelines
Task ID
OperationTask ID
read, writeaaa
Examples
This is an example of configuring the aaa accounting system rp-failover command for default accounting
list:
RP/0/RP0/CPU0:router(config)# aaa accounting system rp-failover default start-stop none
Cisco IOS XR System Security Command Reference for the Cisco CRS Router, Release 4.1
OL-24740-01 9
Authentication, Authorization, and Accounting Commands
aaa accounting system rp-failover