Security: Secure Sensitive Data Management
Configuring SSD
Cisco 350, 350X and 550X Series Managed Switches, Firmware Release 2.4, ver 0.4 377
19
To configure global SSD properties:
STEP 1 Click Security > Secure Sensitive Data Management > Properties.
The following field appears:
Current Local Passphrase Type—Displays whether the default passphrase or a user-
defined passphrase is currently being used.
STEP 2 Enter the following Persistent Settings fields:
Configuration File Passphrase Control—Select an option as described in
Configuration File Passphrase Control.
Configuration File Integrity Control—Select to enable this feature. See
Configuration File Integrity Control.
STEP 3 Select a Read Mode for the current session (see Elements of an SSD Rule).
STEP 4 Click Apply. The settings are saved to the Running Configuration file.
To change the local passphrase:
STEP 1 Click Change Local Passphrase, and enter a new Local Passphrase:
Default—Use the devices default passphrase.
User Defined (Plaintext)—Enter a new passphrase.
Confirm Passphrase—Confirm the new passphrase.
STEP 2 Click Apply. The settings are saved to the Running Configuration file.
SSD Rules Configuration
Only users with SSD read permission of Plaintext-only or Both are allowed to set SSD rules.

Table of Contents

Other manuals for Cisco SG350-10MP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SG350-10MP and is the answer not in the manual?

Cisco SG350-10MP Specifications

General IconGeneral
ModelSG350-10MP
CategorySwitch
PoE Budget130W
Switching Capacity20 Gbps
Forwarding Rate14.88 Mpps
Power SupplyInternal
Ports8 x 10/100/1000 PoE+ + 2 x Gigabit SFP
MAC Address Table Size16K
Jumbo Frame Support9216 bytes
ManagementWeb-based, CLI, SNMP
Operating Temperature0°C to 45°C (32°F to 113°F)
Storage Temperature-20°C to 70°C (-4°F to 158°F)
Operating Humidity10% to 90% relative humidity, non-condensing
Storage Humidity5% to 95% relative humidity, non-condensing
Dimensions (W x D x H)279.4 x 170 x 44 mm (11.0 x 6.7 x 1.73 in)

Related product manuals