Security: Secure Sensitive Data Management
Configuring SSD
378 Cisco 350, 350X and 550X Series Managed Switches, Firmware Release 2.4, ver 0.4
19
To configure SSD rules:
STEP 1 Click Security > Secure Sensitive Data Management > SSD Rules.
The currently-defined rules are displayed. The Rule Type field indicates whether the rule is a
user-defined one or a default rule.
STEP 2 To add a new rule, click Add. Enter the following fields:
User—This defines the user(s) to which the rule applies: Select one of the following
options:
- Specific User—Select and enter the specific user name to which this rule applies
(this user does not necessarily have to be defined).
- Default User (cisco)—Indicates that this rule applies to the default user.
- Level 15—Indicates that this rule applies to all users with privilege level 15.
- All—Indicates that this rule applies to all users.
Channel—This defines the security level of the input channel to which the rule applies:
Select one of the following options:
- Secure—Indicates that this rule applies only to secure channels (console, SCP, SSH
and HTTPS), not including the
SNMP and XML channels.
- Insecure—Indicates that this rule applies only to insecure channels (Telnet, TFTP
and HTTP), not including the SNMP and XML channels.
- Secure XML SNMP—Indicates that this rule applies only to XML over HTTPS and
SNMPv3 with privacy.
- Insecure XML SNMP—Indicates that this rule applies only to XML over HTTP or
and SNMPv1/v2and SNMPv3 without privacy.
Read Permission—The read permissions associated with the rule. These can be the
following:
- Exclude—Lowest read permission. Users are not permitted to get sensitive data in
any form.
- Plaintext Only—Higher read permission than above ones. Users are permitted to get
sensitive data in plaintext only.
- Encrypted Only—Middle read permission. Users are permitted to get sensitive data
as encrypted only.

Table of Contents

Other manuals for Cisco SG350-10MP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SG350-10MP and is the answer not in the manual?

Cisco SG350-10MP Specifications

General IconGeneral
ModelSG350-10MP
CategorySwitch
PoE Budget130W
Switching Capacity20 Gbps
Forwarding Rate14.88 Mpps
Power SupplyInternal
Ports8 x 10/100/1000 PoE+ + 2 x Gigabit SFP
MAC Address Table Size16K
Jumbo Frame Support9216 bytes
ManagementWeb-based, CLI, SNMP
Operating Temperature0°C to 45°C (32°F to 113°F)
Storage Temperature-20°C to 70°C (-4°F to 158°F)
Operating Humidity10% to 90% relative humidity, non-condensing
Storage Humidity5% to 95% relative humidity, non-condensing
Dimensions (W x D x H)279.4 x 170 x 44 mm (11.0 x 6.7 x 1.73 in)