FreeSpeak II for Eclipse | User Guide
l
When overlapping the coverage zones of transceivers to create larger continuous
coverage areas, test the in-between areas with a beltpack for potential areas of low RF
signal; adjust the positioning of the transceivers as needed.
l
Because of potential body shielding during movement, it is useful to place two
transceivers in different locations within larger working areas to minimize low-level
signals and potential signal dropouts.
l
Going between a larger area and a corridor via a door, especially a heavy or shielded
one, or where the walls are thick, place a second transceiver in the corridor near the
doorway to assure continuous coverage.
6.21 Spare parts
The IP Transceiver has the following spare parts.
l
SFP-MMFO-2G-SX 2GBPS MM SX FIBER SFP
l
SFP-SMFO-2G-LX 2GBPS SM LX FIBER SFP
l
453G032-1 Power Supply Unit 12VDC 60W LVL 6 SWITCHING
l
T13532-1 Fan Spare Assembly (2 x Fan and labelled bag or box)
l
T13543-1 Input Filter Assembly (2 x Input Filter and labelled bag or box)
l
T13554-1 Output Filter Assembly (1 x Output Filter and labelled bag or box)
Page 78

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Clear-Com FSII-TCVR-IP-19-US and is the answer not in the manual?

Clear-Com FSII-TCVR-IP-19-US Specifications

General IconGeneral
BrandClear-Com
ModelFSII-TCVR-IP-19-US
CategoryIntercom System
LanguageEnglish

Related product manuals