C-Band Transceiver Revision 1
Remote Control MN/CSAT5060.IOM
6-15
Parameter
Type
Command
(Instruction
Code and
qualifier)
Arguments
for
Command
or
Response
to Query
Description of arguments
Note that all arguments are ASCII
numeric codes between 48 and 57.
Response to
Command
(Slave to Master)
Query
(Instruction
code and
qualifier)
Response to query
(Slave to Master)
Retrieve
Configuration
Status
N/A 113 bytes,
alpha
numerical
Query only.
Used to Query the configuration status of the CSAT
Example: RCS=’cr’
UFQ=5845.0’cr’
DFQ=3625.0’cr’
UAT=12.50’cr’
DAT=01.50’cr’
ONL=YES’cr’
XMT=ON’cr’
AMP=ON’cr’
UMU=OFF’cr’
RCV=ON’cr’
DMU=OFF’cr’
CLD=OFF’cr’
AFR=ON’cr’
EXT=NO ’cr’’lf’
N/A RCS? RCS=x….x (see description for
details of arguments)
Retrieve LNA
Status
N/A 23 bytes,
alpha
numerical
Query only.
Used to Query the LNA status of the CSAT
Example: RLS=’cr’
LCS=ON’cr’
LCW=40’cr’
LFL=1’cr’’lf’
N/A RLS? RLS=x….x (see description for
details of arguments)
Retrieve
Utility Status
N/A 32 bytes,
alpha
numerical
Query only.
Used to Query the utility status of the CSAT
Example: RUS=’cr’
BDR=9600’cr’
REF=087’cr’
USA=0.3’cr’
DSA=0.4’cr’’lf’
N/A RUS? RUS=x….x (see description for
details of arguments)