CSAT with Ethernet Remote Commands
Command Arguments Description of arguments Response to Command Query
MAC address of the unit, reported in hexadecimal.
Example: MAC=00-06-B0-00-D2-A7
Current Active software image, where:
0 = Time protocol disabled
1 = Time protocol enabled
Example: TPE=1 (Time protocol enabled)
Used to set the Time Server IP address for the
Unit. Tx Ethernet management port, in the format:
xxx.xxx.xxx.xxx, where:
xxx.xxx.xxx.xxx is the Time server IP address
Example: IPG = 192.168.001.005
xx.xxx.xxx.xxx.yy
See Note 2
Used set the user’s Local/Remote status in the form x,
where:
1=Serial Remote (RS-232/RS-485)
2=Ethernet
3=Ethernet and Serial
4=FSK
Example: LRS=1 (selects Serial Remote)
Note: Changing LRS to FSK mode may cause some
serial remote commands reply with # code (hardware
resource issues).
Returns the Comtech EF Data part number of the unit.
This
part number is the unit’s DOTCODE at the time it was
manufactured. The DOTCODE may be up to 95 printable
ASCII characters long.
Example: <1/PNM?’cr’
>0001/PNM=CSAT5060-005’cr’’lf’