CSAT-5060 C-Band Transceivers Revision 1
Appendix A MN/CSAT5060.IOM
A–14
CSAT Remote Commands
Parameter
Type Command Arguments Description of arguments
Response to
Command Query
Response to
Query
Redundancy
Controller Box
Toggle
RTG= None Command only.
RTG= sent to the online CSAT will cause the Redundancy
Box to toggle the TX and RX switches.
Example: RTG=
RTG= (message ok)
RTG? (received ok, but
invalid arguments
found)
N/A
N/A
Remote Address
(Physical Address)
SPA= 4 bytes,
numerical
Command or Query.
Physical Address - between 0001 and 9999.
Resolution 0001.
Example: SPA=0890
SPA= (message ok)
SPA? (received ok, but
invalid arguments found)
SPA? SPA=xxxx
See Note 1
Remote Baud rate SBR= 4 bytes Command or Query.
Baud Rate, as follows:
1200 = 1200 baud,
2400 = 2400 baud,
4800 = 4800 baud,
9600 = 9600 baud,
19K2 = 19200 baud.
38K4 = 38400 baud.
Note: Unit responds on the existing baud rate and then
changes to the new baud rate.
SBR= (message ok)
SBR? (received ok, but
invalid arguments found)
SBR? SBR=xxxx
See Note 1
Set RTC Date DAY= 6 bytes,
numerical
A command in the form mmddyy, where; dd = day of the
month, between 01 and 31, mm = month of the year,
between 01 and 12 and yy = year, between 97 and 96
(1997 to 2000, then 2000 to 2096)
Example: DAY=042457 would be April 24, 2057
DAY= (message ok)
DAY? (received ok, but
invalid arguments found)
DAY* (message ok, but
not permitted in current
mode
DAY? DAY=xxxxxx
See Note 1
Set RTC Time TIM= 6 bytes,
numerical
A command in the form hhmmss, indicating the time from
midnight, where hh = hours, between 00 and 23; mm =
minutes, between 00 and 59, and ss = seconds, between
00 and 59
Example: TIM=231259 would be 23 hours, 12 minutes and
59 seconds from midnight.
TIM= (message ok)
TIM? (received ok, but
invalid arguments found)
TIM* (message ok, but
not permitted in current
mode
TIM? TIM=xxxxxx
See Note 1
Clear All Stored
Alarms
CAA= None Command only
Instructs the slave to clear all Stored Events
This command takes no arguments.
CAA= (message ok)
N/A
N/A

Table of Contents