CSAT-5060 C-Band Transceivers Revision 1
Appendix A MN/CSAT5060.IOM
A–9
A.4.2 CSAT Remote Commands
Command = Instruction Code and Qualifier
Arguments apply to Command or to Response to Query
Response to Command = Slave to Master
These codes are used in the Response to Command column:
= Message ok.
? Received ok, but invalid arguments were found
* Message ok, but not permitted in current mode
Description of Arguments:All arguments are ASCII numeric codes between 48 and 57.
Query = Instruction Code and Qualifier
Response to Query = Slave to Master
Note 1 Same format as command argument
Note 2 See Description of arguments for details
CSAT Remote Commands
Parameter
Type Command Arguments Description of arguments
Response to
Command Query
Response to
Query
TX Frequency UFQ= 6 bytes
numerical
Command or Query.
TX Frequency in valid range.
Frequency divisible by 1MHz and 2.5 MHz are allowed.
Example: UFQ= 5901.0
UFQ= (message ok)
UFQ? (received ok, but
invalid arguments found)
UFQ? UFQ=xxxx.x
See Note 1
RX Frequency DFQ= 6 bytes
numerical
Command or Query.
RX Frequency in valid range.
Frequency divisible by 1MHz and 2.5 MHz are allowed.
Example: DFQ=3652.5
DFQ= (message ok)
DFQ? (received ok, but
invalid arguments found)
DFQ? DFQ=xxxx.x
See Note 1
TX Attenuation UAT= 5 bytes
numerical
Command or Query
TX Attenuation, in dB, between 00.00 and 25.00.
Resolution = 00.25 dB.
Example: UAT=12.75
UAT= (message ok)
UAT? (received ok, but
invalid arguments found)
UAT?
UAT=xx.xx
See Note 1
RX Attenuation DAT= 5 bytes
numerical
Command or Query.
RX Attenuation, in dB, between 00.00 and 20.00.
Resolution = 00.25 dB.
Example: DAT=12.75
DAT= (message ok)
DAT? (received ok, but
invalid arguments found)
DAT? DAT=xx.xx
See Note 1

Table of Contents