Low Power Outdoor (LPOD) Amplifier/Block Up Converter (BUC)
Revision 15
Serial Interface Operation 5–25 MN-LPOD
Parameter
Type
(* indicates
End-of-Life)
Controller-to-Target
Instruction Code and
Qualifier
Arguments
for Command
or Query
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
Target-to-Controller
(see Description of
Arguments)
Command Query
Response to
Command
Response
to Query
Local/Remote
State
LRS=
LRS?
1 byte
Command or Query.
Sets or returns Local or Remote state for Indoor SSPA (always in remote mode for
Outdoor SSPA) in the form x, where x=0, 1, 2, or 3::
0=Local
1=Serial
2=Ethernet
3=Serial+Ethernet (DEFAULT)
NOTE: You will always have LRS query access in any mode. The LRS command
is available in all modes as a means of acquiring control so as to limit changes
from being made on multiple interfaces at the same time. Units without a front
panel (e.g., the LPOD) treat an entry of 0 as “reserved” and refuse the command
by returning a mode error. The HTTP Interface prohibits connections unless you
set LRS to accept Ethernet remote control.
COMMAND EXAMPLE: <0001/LRS=3{CR}
LRS=
LRS?
LRS=x
Unit MAC
Address
N/A
MAC?
17 bytes
Query only.
Returns the read-only MAC address of the unit, in hexadecimal format xx-xx-xx-
xx-xx-xx
EXAMPLE: <0001/MAC?{CR}
>0001/MAC=00-06-B0-00-D2-A7{CR}{LF}
MAC=
MAC=xx-
xx-xx-xx-
xx-xx