Low Power Outdoor (LPOD) Amplifier/Block Up Converter (BUC)
Revision 15
Serial Interface Operation 5–26 MN-LPOD
Parameter
Type
(* indicates
End-of-Life)
Instruction Code and
Arguments
for Command
or Query
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
(see Description of
Command Query
Response to
Command
Response
to Query
Operating Point
Returns the maximum operating point of the unit along with its timestamp in the
reply format:
MAXFET=sYYYC mmddyy hhmmss{CR}
MINFET=sYYYC mmddyy hhmmss{CR}
MAXPFT=sYYYC mmddyy hhmmss{CR}
MAXDTP=sYYYC mmddyy hhmmss{CR}
MAXHTS=sYYYC mmddyy hhmmss{CR}
MINHTS=sYYYC mmddyy hhmmss{CR}
MAXOST=sYYYC mmddyy hhmmss{CR}
MAXRFP=sZZ.ZZ mmddyy hhmmss{CR}
MINRFP=sZZ.ZZ mmddyy hhmmss{CR}
Where:
sYYYC is the temperature
sZZ.ZZ is the power
NOTE: Not all LPODs have outside temperature monitor. In which case MAXOST
and MINOST report XXXXX XXXXXX XXXXXX
EXAMPLE: <0001/MOP?{CR}
>0001/mop={CR}
MAXFET=+000C 010208 180729{CR}
MINFET=+000C 010208 180729{CR}
MAXPFT=+000C 010208 180659{CR}
MAXDTP=+000C 010208 180729{CR}
MAXHTS=+050C 010208 180729{CR}
MINHTS=+050C 010208 180729{CR}
MAXOST=XXXXX XXXXXX XXXXXX{CR}
MINOST=XXXXX XXXXXX XXXXXX{CR}
MAXRFP=+00.00 010208 180659{CR}
MINRFP=+00.00 010208 180659{CR}